How the size is calculated
× Ceiling height ÷ 8 ft · ± 10% for shade or sun · + 600 per extra person · + 4,000 for a kitchen
ENERGY STAR sizing chart
- 100–150 sq ft: 5,000 · 150–250: 6,000 · 250–300: 7,000 · 300–350: 8,000
- 350–400: 9,000 · 400–450: 10,000 · 450–550: 12,000 · 550–700: 14,000
- 700–1,000: 18,000 · 1,000–1,200: 21,000 · 1,200–1,400: 23,000 · 1,400–1,500: 24,000
- 1,500–2,000: 30,000 · 2,000–2,500: 34,000
Heating instead? See what a space heater costs to run with the space heater cost calculator.
How to use the calculator
- Enter the room length and width (or the area) and the ceiling height.
- Choose the sun exposure: heavily shaded rooms need about 10% less capacity, very sunny rooms about 10% more.
- Enter how many people regularly use the room and whether it is a kitchen.
- Read the recommended BTU capacity and the equivalent in tons and kilowatts.
ENERGY STAR room air conditioner sizing chart
| Area (sq ft) | Cooling capacity (BTU/h) |
|---|---|
| 100–150 | 5,000 |
| 150–250 | 6,000 |
| 250–300 | 7,000 |
| 300–350 | 8,000 |
| 350–400 | 9,000 |
| 400–450 | 10,000 |
| 450–550 | 12,000 |
| 550–700 | 14,000 |
| 700–1,000 | 18,000 |
| 1,000–1,200 | 21,000 |
| 1,200–1,400 | 23,000 |
| 1,400–1,500 | 24,000 |
The chart assumes 8-ft ceilings and two occupants. The calculator adjusts it for ceiling height, sun, people and kitchens.
Why the right size matters
An undersized unit runs constantly and never reaches the set temperature on hot days. An oversized unit is not better: it cools the air quickly and switches off before it has removed enough moisture, leaving the room cold and clammy, and the frequent on-off cycling wastes energy and wears the compressor. Aim for the recommended size; inverter (variable-speed) units are more forgiving because they can run at low output.
Understanding BTU, tons and watts
- BTU per hour measures how much heat the unit can remove each hour.
- 1 ton of cooling = 12,000 BTU/h (the heat needed to melt one ton of ice in a day).
- 1 kW of cooling capacity ≈ 3,412 BTU/h. This is not the electricity the unit uses — an efficient unit uses roughly a third to a tenth of that.
- CEER / EER / SEER2 ratings describe efficiency: higher is better. A unit with a CEER of 12 uses 1 kW of electricity to deliver 12,000 BTU/h.
Other things that change the load
- Poor insulation, top-floor rooms under a hot roof and large west-facing windows can need 10–20% more capacity.
- Heat-producing equipment — gaming PCs, servers, aquariums and large TVs — adds load; each 100 W of equipment adds about 340 BTU/h.
- For whole-house central air or heat pumps, installers should do a Manual J load calculation rather than rely on rules of thumb.